Power Management Controllers:
Showing 101 to 110 , from a total of 131
EN6326 - Enlogic Metered & Oultlet Switched 16A 0U Vertical PDU, 24 outlets, 20x C13, 4x C19 (2000 Series) EN2.0, 1PH, IEC 60309, 230V, 3.68kVA

The EN6326 Metered & Outlet Switched PDU combines energy metering, power and environmental monitoring with remote outlet on/off switching to monitor, protect, and manage the rack...
PX3-5367V-K2 Raritan BLUE PDU 1PH, 230V AC, 16A, 16 outlets: 14x IEC C-13, 2x IEC C19, Feed Plug IEC60309 16A, 3.7kVA, Zero U vertical PDU, Ethernet, serial and sensor connections PX-5000 (BTO)

PX3-5367V-K2 BLUE Raritan 1PH, 230V AC, 16A, 16 outlets: 14x IEC C-13, 2x IEC C19, Feed Plug IEC60309 16A, 3.7kVA, Zero U vertical PDU,
with Ethernet, serial and sensor...
PX3-5150U-V2 Raritan 63A 400V, 3-Phase Wye (L-N), 43.6kVA, PDU 12xC13, 12x C19 Zero U Vertical PDU, Ethernet, serial, USB-A, USB-B and sensor connections ( PX-5000 Series)

The Raritan PX3 -PX5000 family of high-quality, intelligent rack power distribution units (iPDUs) offers real-time remote power monitoring of current (amps), voltage, power (kVA,...
SVT-C2W36TE-4PAE2M99 ServerTech 32A PDU 18xC13 & 18x CX Outlets. Primary PRO2 HDOT PDU (7.3kW )

C2W36TE-EPAF2M99
32A IND309 - PDU Switched PDU - 7.3kW,
Switched POPS Master PRO2 (36) Alt-Branch HDOT Outlets (24xC13 + 12xCx), 230V 1PH 32A IEC 60309...
BCM2-DIN-G0-KIT-Y01 Raritan BCM2: BRANCH CIRCUIT METER Power Panel Distribution Board Meter: Input: 3 Phase 250A, Output: 24x Single Phase Branch Circuits EXCLUDING Controller

Raritan BCM2: BRANCH CIRCUIT METERS (NO CONTROLLER)
This next generation BCM leverages the same metering and controller technology in Raritan’s 3rd generation rack PDUs...
BCM2-DIN-G0-KIT-Y02 BCM2: 400A BRANCH CIRCUIT METERS Power Panel Distribution Board Meter: Input: 3 Phase 400A, Output: 24x Single Phase Branch Circuits EXCLUDING Controller

BCM2: BRANCH CIRCUIT METERS (NO CONTROLLER)
This next generation 400A BCM leverages the same metering and controller technology in Raritan’s 3rd generation rack PDUs to...
BCM2-DIN-KIT-Y01 Raritan BCM2: BRANCH CIRCUIT METERS & CONTROLLER Power Panel Distribution Board Meter: Input: 3 Phase 250A, Output: 24x Single Phase Branch Circuits INCLUDING Controller

BCM2: BRANCH CIRCUIT METERS & CONTROLLER
This next generation BCM leverages the same metering and controller technology in Raritan’s 3rd generation rack PDUs to track...
BCM2-DIN-KIT-Y02 BCM2: 400A BRANCH CIRCUIT METERS & CONTROLLER Power Panel Distribution Board Meter: Input: 3 Phase 400A, Output: 24x Single Phase Branch Circuits INCLUDING Controller

BCM2: BRANCH CIRCUIT METERS & CONTROLLER
This next generation 400A BCM leverages the same metering and controller technology in Raritan’s 3rd generation rack PDUs to...
BCM2-DIN48-G0-KIT-Y01 BCM2: BRANCH CIRCUIT METERS Power Panel Distribution Board Meter: Input: 3 Phase 250A, Output: 48x Single Phase Branch Circuits EXCLUDING Controller

BCM2: BRANCH CIRCUIT METERS (NO CONTROLLER)
This next generation BCM leverages the same metering and controller technology in Raritan’s 3rd generation rack PDUs to track...
BCM2-DIN48-G0-KIT-Y02 BCM2: 400A BRANCH CIRCUIT METERS Power Panel Distribution Board Meter: Input: 3 Phase 400A, Output: 48x Single Phase Branch Circuits EXCLUDING Controller

BCM2: BRANCH CIRCUIT METERS (NO CONTROLLER)
This next generation 400A BCM leverages the same metering and controller technology in Raritan’s 3rd generation rack PDUs to...